The single zone premium wall thermostat has 5 different operating modes and a sleep setting to ensure optimal comfort throughout your RV or camper.
Auto Mode: Allows the system to automatically change between cool mode and heat mode based on the room temperature. When the room temperature reaches 77 degrees F, the system will operate in cool mode. When the room temperature drops below 68 degrees F, the system will operate in heat mode (only when furnace is enabled).
Cool Mode: Cycles the compressor on and off based on the room temperature and the temperature set-point. When the compressor is running, the fan will be turned on to either low, medium, high, or auto. On auto fan, the fan speed varies depending on the difference between the temperature set-point and room temperature.

Heat Mode (only when furnace is enabled): Cycles the compressor on and off based on the room temperature and the temperature set-point. When the compressor is running, the fan will be turned on to either low, medium, high, or auto. The fan speed selection only applies to the fan speed on the air conditioner and not the fan speed of the furnace.
Fan Mode: Operates continuously at low, medium, or high speed.
Dry Mode: Runs the compressor continuously when the room temperature is higher than the temperature set-point. When the room temperature is lower than the temperature set-point, the compressor cycles on for 10 minutes and off for 6 minutes to maintain your desired temperature. The fan speed runs continuously at low speed.
Sleep Setting: Automatically increases your temperature set-point 2 degrees every hour up to 2 hours. After 2 hours, the fan is set to low speed. This allows your unit to use less power overnight and reduces noise while you sleep.